| Conventional Fire Panels | Addressable Fire Panels |
| Conventional Fire Detectors | Addressable Fire Detectors |
| Conventional Sirens | Addressable Devices |
| Conventional Accessories | |
![]() |
MAG2: 2 zones fire panel, metal box Conventional fire alarm control panel, 2 fully monitored fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 "fire" and 1 "fault" relay output, walk test, metal box. Catalogue number: 31020002 Conventional fire alarm control panel: -2 fully monitored fire zones with up to 20* automatic detectors; -2 monitored siren outputs; -1 “fire” and 1”fault” relay output; -walk test. |
![]() |
MAG4: 4 zones fire panel, metal box Conventional fire alarm control panel, 4 fully monitored fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 “fire” and 1”fault” relay output, one man test, metal box. Catalogue number: MAG4 metal box - 31020001 Conventional fire alarm control panel, 4 fully monitored fixed fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 “fire” and 1”fault” relay output, one man test. Functional features: One 12 V / 7 Ah battery for stand-by supply; Manual trigger of the fire alarm; Class change input; Abundant LED indications; Security key for switching over between access levels 1 and 2; Independent Enable/Disable of each zone and sounders; Metal box; Consumption – 50 mA. |
![]() |
MAG2P: 2 zones fire panel, plastic box Conventional fire alarm control panel, 2 fully monitored fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 “fire” and 1”fault” relay output, walk test. Catalogue number: MAG2P plastic box - 31020018 Conventional fire alarm control panel, 2 fully monitored fixed fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 “fire” and 1”fault” relay output, walk test. Functional features: One 12V/7Ah battery for stand-by supply; Manual trigger of the fire alarm; Class change input; Abundant LED indications; Security key for switching over between access levels 1 and 2; Independent Enable/Disable of each zone and sounders; ABS plastic box; Consumption – 50 mA. |
![]() |
MAG4P: 4 zones fire panel, plastic box Conventional fire alarm control panel, 4 fully monitored fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 “fire” and 1”fault” relay output, one man test. Catalogue number: MAG4P plastic box - 31020019 Conventional fire alarm control panel, 4 fully monitored fixed fire zones with up to 20 automatic detectors, 2 monitored siren outputs, 1 “fire” and 1”fault” relay output, one man test. Functional features: One 12 V / 7 Ah battery for stand-by supply; Manual trigger of the fire alarm; Class change input; Abundant LED indications; Security key for switching over between access levels 1 and 2; Independent Enable/Disable of each zone and sounders; ABS plastic box; Consumption – 50 mA. |
![]() |
MAG8plus: 8/16 zones conventional fire alarm panel 8 zones conventional panel, expandable up to 16 zones.
Catalogue number: 31020021 Conventional fire alarm control panel; 8 fully monitored fire zones; expandable up to 16 zones; automatic fire detectors to each zone: up to 32; 4 monitored siren outputs (possible expanding up to 12 siren outputs); 1 “fire” and 1 “fault” relay output; resettable fuses; one man test; repeater interface; operates with 1 battery 12 V/18 Ah; certificated by EN54-2/4. |
![]() |
Zone expander: 4 zones 4 zone expander for MAG8plus. Catalogue number: 33000056 Expander for 4 zones for MAG8plus control panel. |
![]() |
Sounder Expander: 4 sounders Expander for 4 Sounder outputs for MAG8plus fire alarm panel. Catalogue number: 33000211 4 siren outputs expander module for MAG8plus conventional fire alarm panel. A correspondence between a zone number and a siren number has been introduced (1st zone corresponds to 1st siren, 2nd zone - to 2nd siren and so on) with the purpose for quick finding the place of fire. |
![]() |
MR8 - relay module Relay module - 8 relays for MAG8Plus. Catalogue number: 33000053 Relay module - 8 relays for MAG8Plus. Every module provides 8 system relay outputs. The type of the relay contacts is programmable. The module is intended to transmit zone fire indication to a remote site. Consumption, nom/max: 8/10 mA. |
![]() |
ML MAGlogger Memory LOG Module Catalogue number: 33000330 MAGlogger is a LOG module for recording and viewing of events in MAG8Plus Fire Control Panel. All of the events are stored in a non-volatile memory. The LOG module has a real time clock powered from own battery. The information for the events is received by interface with the MAG8plus Fire Control Panel. Functional Characteristics * Real time clock with built-in battery * LOG Memory for 510 events * Input RESET * Relay output RESET * MAG8Plus special interface * Operation keypad – 4 buttons * LCD display with backlight * Multilanguage menus - 8 languages * Small size and possibility for mounting into the MAG8Plus box Technical Specifications * Operation power supply 17 ÷ 30 VDC * Nominal voltage 24 VDC * Consumption in stand-by mode (average) 18 mA * Consumption with activated backlight 50 ± 1mA * Max. consumption with activated backlight and relay output 74 ± 1mA * Clock accuracy max. 7 sec/month * Dimensions of MAGlogger PCB 125х66mm |